Vibration Isolation Case Studies
DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.
Series
Equipment Type
Manufacturer
All Case Studies

Lemoneyex SN3-4500M Plus UD350 Vibration Measurement Report (2020-10-14)
Vibration measurement worksheet dated 2020-10-14 at Lemoneyex corporate R&D center (4F): UD350 floor vs top-plate VC-Class summary (Z/X/Y), B&K PULSE 14 measurement-equipment photos, and 1/3-octave Floor vs Table VC-Class plots. Generic VC criterion table and VC curve figures from the DOCX reference block are published as the site Reference markdown table only (no separate gallery assets).
Lattice Semiconductor Phils ZEISS EVO 18 DVIA-U1000 (200203R4 · P15) Remote tuning — Philippines — 2020.10.08
DVIA-U1000 serial 200203R4 with ZEISS EVO 18 (project P15) at Aeon Center, Alabang, Philippines via channel partner remote tuning worksheet. Dates of setup and reporting 20.10.08 per form; Measurement date 20.10.08 (Thu). Publication includes onsite equipment photograph plus UB1000/DVIA internal-program Z / X / Y screenshots (transfer-function views) as exported from Word.

Schaeffler DVIA-MB1000 (P914, 200730R1) Internal program performance — 2020.10.05
DVIA-MB1000 worksheet P914 (platform serial 200730R1) at Schaeffler; measurement and reporting dated 2020.10.05 (operator Choi, HyoungMun, Daeil System). Summary transmissibility table and Korean site notes follow the DOCX; MB1000 internal-program plots are published under Z, X, and Y axis headings. The centred title-line decorative raster is not republished.

ZEISS GEMINI SEM 500 DVIA-MB1000 (P132 / 190614R2) Internal program performance — 2020.09.24
DVIA-MB1000 worksheet P132 (serial 190614R2) for a ZEISS_GEMINISEM 500 at Xi'an Jiaotong University (measurement and reporting dated 2020.09.23–2020.09.24; operator Choim, HyoungMun, Daeil System). Summary table transmissibility values and overview text follow the DOCX; MB1000 internal-program screenshots align with Z axis, X axis, and Y axis headings per §2a embed mapping (rId9–11 → image2–4). The decorative raster on the centred MB1000 title line (rId8 / image1) is not republished.

Wangbo DVIA-MO1000 (P191) Remote Tuning Installation Report — September 22, 2020
MO1000 handout for DVIA-MO1000 serial P191 (200729R1) at Kunshan: concentric distance measuring equipment, remote tuning on 2020-09-22. Summary transmissibility table and Z–X–Y internal-program screenshots are published; the setup-title decoration raster before Overview is omitted.

FEI Apreo C DVIA-MB1000 (P162 / 200414R1) Internal program performance — 2020.09.18
DVIA-MB1000 worksheet P162 (serial 200414R1) for a FEI Apreo C at NORINCO GROUP in Zhanjiang (measurement and reporting dated 2020.09.17–2020.09.18; operator Choim, HyoungMun, Daeil System). Summary table transmissibility values and overview text follow the DOCX; MB1000 internal-program screenshots align with Z axis, X axis, and Y axis headings per §2a embed mapping. The decorative raster on the centred MB1000 title line is not republished.