Vibration Isolation Case Studies
DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.
Series
Equipment Type
Manufacturer
All Case Studies

Southern University of Science and Technology Helios G4 UC DVIA-MB1000 (191121R3 · P150) Remote measurement — Internal program plots — 2020.08.25
DVIA-MB1000 serial 191121R3 (project P150) for Helios G4 UC via channel partner; END USER Southern University of science and technology per the summary table with installation place Shenzen, 1st floor. Internal-program plots align with **Z axis**, **X axis**, and **Y axis** headings in the Word document. The decorative graphic on the centered setup-heading paragraph is not republished.

ZEISS EVO10 UB1000 P16 Remote Tuning Installation Report (190923R7, 2020-08-24)
UB1000 (S/N 190923R7, P16 remote tuning worksheet) vibration check after active mounting on ZEISS EVO10 at 高意通讯(深圳)有限公司 6th floor, Shenzhen, delivered. Operator Kim, Doohyun; setup and report 2020-08-24. Publication includes the UB1000 setup photograph, 2/5/10 Hz transmissibility summary (Z/X/Y), and UB1000 internal-program Z/X/Y axis plots.

Suzhou Weixin Electronics Zeiss Sigma 500 DVIA-MB1000 (190109R5 · P109) Remote tuning — Internal program plots — 2020.08.20
DVIA-MB1000 serial 190109R5 (project P109) for Zeiss Sigma 500 at Suzhou Weixin Electronics (1st floor), remote tuning worksheet dated 2020.08.20. VC-Class summary grid cells are blank in the source; MB1000 internal-program Z, X, and Y screenshots follow Word document order; the decorative raster directly under the centred setup title line is not republished.

MFLEX Suzhou Zeiss Sigma 500 DVIA-MB1000 (190109R5 · P109) Remote measurement — Internal program plots — 2020.08.20
DVIA-MB1000 serial 190109R5 (project P109) for Zeiss Sigma 500 via channel partner; END USER 苏州维信电子有限公司 (MFLEX Suzhou) and installation site Suzhou, 1st floor. Internal-program plots follow **Z axis**, **X axis**, and **Y axis** headings as in the Word document. The smaller JPEG embedded on the centered setup heading block (rId8 / image1.jpeg) is treated as header decoration and not republished. The source worksheet has no Reference / Generic Vibration Criteria section.

Zhejiang Zili Co., Ltd. Zeiss Sigma 500 DVIA-MB1000 (200715R3-1 · P186) Remote measurement — Internal program plots — 2020.08.19
DVIA-MB1000 serial 200715R3-1 (project P186) reported via /channel partner at Zhejiang Zili Co., Ltd., Shaoxing. The setup table lists Target equipment Zeiss sigma 500 while the Overview block’s Equipment Model line reads Thermo scientific Scios 2 — both lines are reproduced verbatim from the Word form. Figures follow Z axis, X axis, and Y axis as in Word; the ornamental photo directly under the centered setup heading is not republished.

Zeiss G300 DVIA-MB1000 (200319R2 · P164) Remote measurement — Internal program plots — 2020.08.17
DVIA-MB1000 serial 200319R2 (project P164) for Zeiss G300 with END USER TCL华星光电技术有限公司 (CSOT affiliate in the workbook) on the /channel-partner worksheet dated 20.08.17. Operator Munho Noh; place of installation and place of measurement lines read Shenzen exactly as in Word. Published internal-program screenshots follow the Z axis, X axis, and Y axis subtitles in workbook order after the worksheet heading line; the decorative title-band graphic under MB1000_200319R2(P164) Set up is omitted from the gallery.