Hitachi SU8240(Room 1C06-01) DVIA-U350 Installation Report
Installation Report
DVIA-ULF Series
07-29-2024

Hitachi SU8240(Room 1C06-01) DVIA-U350 Installation Report

Hitachi SU8240(Room 1C06-01) DVIA-U350 Installation

Hitachi SU8240(Room 1C08-01) DVIA-U350 Installation Report
Installation Report
DVIA-ULF Series
07-29-2024

Hitachi SU8240(Room 1C08-01) DVIA-U350 Installation Report

Hitachi SU8240(Room 1C08-01) DVIA-U350 Installation

Thermo Fisher Spectra 300 S/TEM DVIA-MB3000 (240415R3-2) — Shenzhen Weiguang, 2024-07-26

Shenzhen Weiguang — Thermo Fisher Spectra 300 S/TEM on DVIA-MB3000 serial 240415R3-2. STONE-300 internal program performance plots (Vertical, Left to Right, Front to Back) from the 2024.07.26 measurement; reporting dated 2024.08.07. Engineer Chaewon Lee (DAEIL SYSTEMS).

Thermo Fisher Scientific Spectra 300 S/TEM DVIA-STONE-300 (240415R3-1) internal program performance report

DVIA-STONE-300 internal program handout (serial 240415R3-1) with Thermo Fisher Scientific Spectra 300 S/TEM as target equipment. Measurement 2024-07-25; published figures are vertical, left-to-right, and front-to-back internal program results; decorative title-block raster omitted from web. Generic Vibration Criteria published as markdown table only (no separate VC figure).

Shanghai Institute of Ceramics CAS — Thermo Fisher Spectra 300 TEM DVIA-STONE-300 (231113R4-1) Internal Program Report

DVIA-STONE-300 (serial 231113R4-1) STONE internal program performance captures for Thermo Fisher Spectra 300 TEM at the Shanghai Institute of Ceramics, Chinese Academy of Sciences — Analysis & Testing Research Center. Overview, system lines, and metadata follow the report wording; only Vertical, Left to Right, and Front to Back plots are published. The decorative raster inserted under the (STONE-300_ 231113R4-1 Set up) title block in the DOCX is omitted from the public page.

DVIA-STONE-300PLUS (210824R1-1) Thermo Fisher Spectra 300 TEM — Internal Program Set-up (measurement 2024.07.19)

DVIA-STONE-300PLUS worksheet (serial 210824R1-1) titled (STONE-300PLUS_ 210824R1-1 Set up) with setup 24.07.19 and reporting 24.07.20. Target equipment is Thermo Fisher Spectra 300 TEM for Peking University Huairou (北大怀柔) with installation place 北京. Overview and field lines follow the report verbatim; STONE-300PLUS internal program screenshots are published under Vertical, Left to Right, and Front to Back only. There is no separate vibration specification section, measurement summary table, or Reference section in the source.