ZEISS FE-SEM GeminiSEM 300 DVIA-M1000 (240415R3-4) Installation Report

DVIA-M1000 installation report — ZEISS FE-SEM GeminiSEM 300 (serial 240415R3-4), field package. Overview states the platform is appropriately installed and functioning as intended. The published form has no vibration specification section and no measurement summary table. Prepared for, location, and tuning request are not filled (N/A). Equipment condition: The equipment is installed. Published figures: UI-program Transmissibility (vertical, left to right, front to back) and on-site equipment photo; Reference uses the standard Generic Vibration Criteria markdown table (no separate reference graphic).

Tier-1 Semiconductor DSR Park Systems NX10 DVIA-T45 (240624R3) Installation Report

DVIA-T45 (serial 240624R3) tuning and vibration measurement versus KAKO/KURASHIKI at Tier-1 Semiconductor DSR with Park Systems AFM NX10: VC/Narrow-band/Transmissibility comparison plots and 25‑minute vertical floor data. Measurement July 2024; written July 2024.

Chengdu BYD Semiconductor ZEISS GeminiSEM 360 DVIA-M1000 (231204R5) Internal Program Performance — 2024.07.12

Chengdu BYD Semiconductor — ZEISS GeminiSEM 360 on DVIA-M1000 serial 231204R5. M1000 internal program performance captures (Vertical / Left to Right / Front to Back) from the 2024.07.12 handout; header-band raster before the form tables is not republished.

Tier-1 Semiconductor Chengdu ZEISS GeminiSEM 360 DVIA-M1000 (231204R6) Installation Report — 2024.07.12

DVIA-M1000 serial 231204R6 worksheet for ZEISS GeminiSEM 360 SEM at Tier-1 Semiconductor Chengdu, with setup and reporting on 2024.07.12. The issued form publishes the overview text, site lines, GeminiSEM identification, Chaewon Lee (DAEIL SYSTEMS), and internal-program performance plots labeled Vertical, Left to Right, and Front to Back. Decorative masthead-only graphics above the worksheet title block are omitted from the public gallery.

TCL ZEISS SEM Sigma360 DVIA-M1000 (240517R5) Installation Report

DVIA-M1000 installation report (serial 240517R5) for ZEISS SEM Sigma360. Overview matches the published form. Equipment condition: The equipment is installed. Published figures include UI-program plots as listed; Reference uses the standard Generic Vibration Criteria markdown table.

Shanghai Jiaotong University Thermo Fisher Apreo 2S DVIA-MB1000 (210701R6) Installation Report — 2024.07.06

DVIA-MB1000 abbreviated MB1000 worksheet (serial 210701R6 in the issued title line). Setup dated 24.06.24 and reporting dated 24.07.06; measurement date 2024.06.24 (Monday) at Shanghai Jiao Tong University with operator Byeonghun Cho from DAEIL SYSTEMS. END USER reads “Shanghai” on the checklist table; Thermo Fisher Apreo 2S FE-SEM and installation site Shanghai Jiaotong University match the Target equipment / Place of installation rows. The Overview carries the DVIA‑MB1000 standard sentence plus equipment bullets as printed. No vibration isolation system table, vibration specification, equipment status, tuning request, measurement summary table, or Reference section appears in the source. The MB1000 internal program section publishes three plots under Vertical, Left to Right, and Front to Back. Decorative centered header/table layout text from Word is omitted as non-content.