ZEISS Crossbeam 550 DVIA-MB1000 (P204 / 201013R2) Internal program performance — 2021.01.19

DVIA-MB1000 worksheet P204 (serial 201013R2) for ZEISS Crossbeam 550 with (measurement 2021.01.18, report 2021.01.19; operator Choi, HyoungMun, Daeil System). Summary transmissibility table and overview text match the DOCX; MB1000 internal-program screenshots follow Z, X, and Y axis headings per §2a embed mapping (rId9→image2 … rId11→image4). The decorative raster under the centred MB1000 title line (image1 / rId8) is not republished.

Thermo Fisher DVIA-MB1000 MB1000 Internal Program Worksheet (P196 · 200925R5) — 2021.01.18

MB1000 P196 handout for DVIA-MB1000 serial 200925R5 with Thermo Fisher–branded target equipment: worksheet image under the title row, transmissibility summary at 2 / 5 / 10 Hz, and Signal-program internal performance plots for Z, X, and Y (DOCX §2a: image1 setup, image2–4 axis plots). Appears in the source filename; END USER, place of installation, and place of measurement cells are blank on the sheet.

Hitachi HT7800 DVIA-MB1000 (200429R5 / P190) Internal Program Performance — Hainan Medical College — 2021.01.13

DVIA-MB1000 P190 serial 200429R5 — MB1000 internal-program handout for Hainan Medical College with Hitachi HT7800; report and measurement dates 2021-01-13. Operator Choi, HyoungMun (DAEIL SYSTEMS). Transmissibility summary table and Z / X / Y program plots (DOCX §2a: media image2–4 under axis headings; centered bitmap after the title line is not republished).

Shenzhen Yan Yi New Materials Zeiss Gemini Sigma 300 DVIA-MB1000 (200918R1 · P192) Remote measurement — Internal program plots — 2021.01.11

DVIA-MB1000 serial 200918R1 (project P192) for Zeiss Gemini sigma300 at Shenzhen 9F for 深圳市研一新材料有限公司, reported in remote tuning handout dated 2021.01.11. Transmissibility summary and MB1000 internal-program Z, X, and Y axis screenshots follow Word order; decorative raster under the “MB1000_200918R1P(192) Set up” title line is not republished.

BOE Tescan solaris X DVIA-MB1000 (201020R2 · P201) Remote tuning — 2020.12.24

DVIA-MB1000 serial 201020R2 (project P201) for Tescan solaris X reported via /channel partner; installation and measurement site lines read BOE on 2020.12.24 with engineer Doohyun Kim. Published plots follow Z, X, and Y axis captions as in Word; the centered decorative photograph inserted immediately under the title line is not republished.

POSTECH Scienta Omicron PEEM DVIA-U700 (P18) Replacement Installation Report — Pohang

DVIA-U700 compact installation worksheet (P18 replacement) at POSTECH Department of Physics with Scienta Omicron-IEF/TOF PEEM at RIST HQ 1st floor. Setup 20.12.18, reporting 20.12.23; operator Choi, Hyoung Mun from DAEIL SYSTEMS; business-trip line 17.12.27~17.12.29. Publication includes overview measurement figures, performance summary plots, U700 internal-program Z/X/Y screenshots, and Octave Band Result (BASE: Floor, TOP: Above Active) Z/X/Y plots in Word segment order (header image1 omitted).