FUJIAN ZI JIN TONG BO Axia ChemiSEM LoVac DVIA-U1000 (220718R11) Installation Report — Fujian
DVIA-U1000 compact installation worksheet (serial 220718R11) at FUJIAN ZI JIN TONG BO with Axia ChemiSEM LoVac. Setup 23.03.07, reporting 23.03.10, business-trip line 17.12.27~17.12.29; Overview measurement dated 2023.03.07 (Tuesday). Publication includes setup photograph and U1000 internal-program Z / X / Y axis screenshots. Decorative header bitmap (image1) omitted.

Shanghai Shengjian Environmental System Technology Sigma300 DVIA-U1000 (220919R7) Installation Report — Shanghai
DVIA-U1000 compact installation worksheet (report line 220919R7) at Shanghai Shengjian Environmental System Technology Co., Ltd with Zeiss Sigma300. Setup 2023.03.09, reporting 2023.03.10, business-trip line 17.12.27~17.12.29; Overview measurement dated 2023.03.20 (Monday). Publication includes equipment setup photograph and U1000 internal-program Z / X / Y screenshots. Decorative header bitmap (image1.png) omitted.

Yale School of Medicine Zeiss Versa 610 DVIA-MB3000 VEC (230110R4) Installation Report — 2023.03.10
DVIA-MB3000 (serial 230110R4, platform DVIA-MB3000-1370x2180) VEC installation worksheet at Yale School of Medicine Child Study Center (350 George St, New Haven, CT) with Zeiss Versa 610. Includes UI program transmissibility (Z/X/Y), VEC measurement plots (transmissibility, floor VC, active VC per axis), an installed equipment photograph, and Reference as the standard Generic Vibration Criteria markdown table (reference criterion graphic not republished). Engineer Youngha Lee (DAEIL SYSTEMS).

JEOL JEM 1400 Flash DVIA-M1000 (220126R7-3) Installation Report — Sun Yat-Sen University
DVIA-M1000 installation report (serial 220126R7-3) for JEOL JEM 1400 Flash TEM at Sun Yat-Sen University, Guangdong, China,. VC curves (vertical and left-to-right), front-to-back transmissibility, and equipment photo from the published handout. Report written date 23.05.22. Reference uses the standard Generic Vibration Criteria markdown table only.

RIYUE HEAVY INDUSTRY EVO10 NINGBO DVIA-U1000-910×1140 mm (220512R5, UB700 form) Installation Report
Compact DVIA-U1000 (910×1140 mm plate, serial 220512R5) installation worksheet for RIYUE HEAVY INDUSTRY with EVO10 at NINGBO. Tuning 23.03.03, written 23.03.07; business-trip line 17.12.27~17.12.29. Z / X / Y-axis internal-program transmissibility plots plus an equipment photograph; omitted non-informative decorative header raster.

FUJIAN ZI JIN TONG BO Axia ChemiSEM LoVac DVIA-UB700 Installation Report (220718R11)
Formal DVIA-UB700 installation report worksheet (serial 220718R11) for Axia ChemiSEM LoVac at FUJIAN ZI JIN TONG BO — Z / X / Y axis Transmissibility plots and installation photograph from the UB700 report dated 2023.03.07 line. Decorative cover bitmap from the DOCX (image1.PNG) omitted. Distinct companion to the DVIA-U1000 internal program screenshots case with the same serial.