Vibration Isolation Case Studies

DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.

Series

Equipment Type

Manufacturer

All Case Studies

1264 case studies
East China Microelectronics Thermo Fisher Apreo 2C HiVac DVIA-M1000 (230602R4) Set-up Report — Hefei

DVIA-M1000 handout (serial 230602R4) for Thermo Fisher Apreo 2C HiVac at East China Microelectronics in Hefei. Setup 24.04.23, reporting 24.07.05, measurement dated 2024.04.23 (Tuesday). Published imagery matches the source: installation view under the MB1000 set-up title plus M1000 internal program results labeled Vertical, Left to Right, and Front to Back. The source worksheet has no vibration specification section, measurement summary table, or Reference appendix.

ZEISS Crossbeam300 SEM DVIA-M1000 (230701R3) Installation Setup Handout

Short setup-style handout for serial 230701R3 covering a ZEISS SEM Crossbeam300 on DVIA-M1000. Reporting block lists Chaewon Lee, setup date 2023.12.01 (measurement dated the same weekday), reporting 24.07.05, and business trip dates 17.12.27~17.12.29. Overview states the isolation platform is appropriately installed and functioning as intended. Blank fields remain N/A where the form has no entry. Published figures only: M1000 internal-program Vertical / Left-to-Right / Front-to-Back plots; no standalone equipment raster in the supplied document; decorative title-block graphics omitted.

Dongguan Jinuo Thermo Fisher Helios 5 DVIA-MB1000 (230712R3-2) Installation Report

DVIA-MB1000 onboard program results (serial 230712R3-2) for Thermo Fisher FE-SEM Helios 5 at Dongguan Jinuo END USER — Guangzhou site. Operator Byeonghun Cho; measurement 2024.06.27 / reporting 24.07.05. Screenshots publish Vertical, Left to Right, and Front to Back per the embedded program labels (section heading text follows the source Word template). Decorative title-block raster omitted.

DVIA-M1000 Internal Program Measurement (230821R3-1)
Installation Report
DVIA-M Series
07-05-2024

DVIA-M1000 Internal Program Measurement (230821R3-1)

DVIA-M1000 report: cover line M1000_ 230821R3-1 (serial 230821R3-1); measurement block uses MB1000 internal program captions. End user, installation site, and equipment model are not stated in the handout (N/A). Setup 24.03.18, reporting 24.07.05, on-site measurement 2024.03.18; operator Chaewon Lee (DAEIL SYSTEMS). Published UI screenshots: Vertical, Left to Right, and Front to Back only — the handout includes no separate Reference section. Decorative header graphics: none in word/media beyond these three figures.

ECOMI DVIA-M1000 MB1000 internal program performance (230821R3-1, reporting 2024.07)

DVIA-M1000 field note for ECOMI (printed serial 230821R3-1 on the cover line). Setup 2024.03.18, reporting 2024.07.05, measurement dated 2024.02.01. Publishes MB1000 internal-program screenshots labeled Vertical, Left to Right, and Front to Back. Abbreviated Word layout: no site equipment photo block and no Reference appendix in the source.

Xi'an Jiaotong University ZEISS Sigma 300 DVIA-M1000 (231009R3) Installation Report

DVIA-M1000 abbreviated worksheet (serial 231009R3). Setup dated 24.03.22 and reporting dated 24.07.05; measurement date 2024.03.15 (Wednesday) at Xi'an Jiaotong University with operator Chaewon Lee from DAEIL SYSTEMS. END USER matches the institution; target equipment ZEISS Sigma300 and installation site Xi'an as on the form. The Overview block states the standard DVIA-M1000 sentence only. No vibration specification, equipment status, tuning request, measurement summary table, or Reference section appears in the source. The internal-program section title reads “M1000 internal program performance measurement result”; published figures are three plots under Vertical, Left to Right, and Front to Back. Decorative header graphics from the Word file are omitted from public copy.