Vibration Isolation Case Studies

DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.

Series

Equipment Type

Manufacturer

All Case Studies

1264 case studies
Tier-1 Electronics Component Manufacturer ZEISS Xradia 620 Versa DVIA-MB3000 (201201R2) Installation Report — 2026.02.09

On-site worksheet dated 2026.02.09 for DVIA-MB3000 serial 201201R2 supporting ZEISS Xradia 620 Versa at Tier-1 Electronics Component Manufacturer (Gumi Plant 4, X-ray CT Room). With customer equipment **Turned on/IDLE**, tuning and vibration measurement were performed and results are plotted on VC curves alongside an equipment-spec diagram. Measurement summary PASS/FAIL is tabulated below; Generic Vibration Criteria are published here as the standard markdown Reference table without a standalone reference illustration.

Hitachi SEM Hitachi SU3800SEPlus DVIA-ML1000 (250304R4) Installation Report

DVIA-ML1000 installation report (serial 250304R4).

Omicron STM DVIA-M1000 (2309050R3) Installation Report — Beijing Academy of Quantum Information Sciences

DVIA-M1000 installation handout (serial 2309050R3) for an Omicron STM at Beijing Academy of Quantum Information Sciences. Vibration specification is N/A in the form. UI program autospectrum and transmissibility plots (vertical, left-to-right, front-to-back), equipment photo, and Reference as the standard Generic Vibration Criteria markdown table only; header decoration and reference EMF omitted from public copy.

Shanghai Pumi PrMat STM DVIA-M1000 (241101R2) Installation Report — Huasheng Lianying Vibration Damping Platform

DVIA-M1000 installation report (serial 241101R2) for Shanghai Pumi Precision Instrument Technology Co., Ltd. PrMat STM at Huasheng Lianying Vibration Damping Platform, Shanghai, China. Overview states the DVIA-ML1000 platform is appropriately installed and functioning as intended. Vibration specification and tuning request are N/A in the form. Equipment Condtion line is reproduced verbatim from the report. Measurement summary compares floor vs DVIA-M1000 with PrMat STM turned on/IDLE. Measurement Data Obtained via UI Program publishes VC curves, Autospectrum, and Transmissibility for vertical, left-to-right, and front-to-back axes; equipment picture; Reference is the standard Generic Vibration Criteria markdown table only (no separate reference graphic).

Tier-1 Semiconductor Icheon Applied Materials PROVision 10 DVIA-P7000 Installation Report

Tier-1 Semiconductor Icheon Applied Materials 3E eBeam Metrology PROVision 10 DVIA-P7000 installation report.

Hitachi HT7800 TEM DVIA-ML1000 Installation Report (2nd visit 2026-01-21)

SN 250912R5 — 2nd tuning; Hitachi HT7800 TEM. UI program plots (7 figures).