Shanghai Institute of Space Propulsion ZEISS Sigma300 DVIA-M1000 (230701R3) Installation Report
DVIA-M1000 handout for serial 230701R3 with ZEISS Sigma300 target equipment at Shanghai Institute of Space Propulsion. Overview, setup and reporting dates, measurement session on 2023.10.10, and laboratory photograph. M1000 internal program performance screenshots for Z, X, and Y axes. Reference and vibration-limit tables were not included in this handout.

Jinhae Armed Forces Financial Management Command ZEISS FE-SEM EVO10 DVIA-MB1000 (230704R4) Installation Report
DVIA-MB1000 installation report (serial 230704R4) for ZEISS FE-SEM EVO10 at Jinhae Armed Forces Financial Management Command. Published figures: ZEISS EVO10 specification VC curve (equipment vibration limits), Vertical / Left-to-right / Front-to-back Transmissibility and VC curves. Reference uses the standard Generic Vibration Criteria markdown table only (no separate reference graphic).

LG Gemini 560 DVIA-M1000 (230804R2) Installation Report
DVIA-M1000 Gemini 560 handout archived as M1000_230804R2_23.09.04. Summary rows list Nanjing, remark Good Performance, and end user LG. Overview states the DVIA-M1000 platform is appropriately installed and functioning as intended. Measurement lines and equipment model Gemini 560 precede UI plots under M1000 internal program performance measurement result for Z / X / Y axes. Published images are those three screenshots only; LG title-block déc raster omitted.

TESCAN SEM MAGNA DVIA-M1000 (230908R2-1) Installation Report
DVIA-M1000 installation report (serial 230908R2-1) for a TESCAN SEM MAGNA at CNITECH, Ningbo. Field summary lists setup and reporting dates, overview, equipment installation photo, and UI-program Z / X / Y transmissibility and coherence plots.

Zhongke Ecomi DVIA-M1000 Internal Program Measurement (231025R2) — Beijing
Zhongke Ecomi site Beijing; DVIA-M1000 overview (measurement 2024.08.29); source file serial 231025R2 (reporting 24.09.09). Published Vertical, Left to Right, and Front to Back screenshots under the internal program caption. Header-only decoration omitted.

Zhongke Ecomi DVIA-M-AST Internal Program Measurement (231025R2) — Beijing
Zhongke Ecomi, Beijing: DVIA-M-AST internal-program measurement on 2024.05.16; platform setup 24.05.30 and report date 24.07.05 (serial 231025R2). Published results: Vertical, Left to Right, and Front to Back. Decorative cover artwork is not shown on this page.