Qualcomm Wuxi ZEISS SIGMA HD DVIA-MB1000 (MB1000 P43) China relocation trip report — 2017.10.26

Korean-language China business-trip worksheet for MB1000_P43 reset-up after equipment relocation: target ZEISS-SIGMA HD at Qualcomm Wuxi, second-stage relocation and re-tuning by Daeil Systems (Choi Hyoung-mun), measurement on 2017-10-24. The public page follows the DOCX stream order (§2a): decorative title strip bitmap (image1, 408×83) is omitted; VC-Class chart (image2) under the report title, VC-Class summary table and narrative as issued, MB1000 internal-program Z/X/Y captures, and octave-band Z/X/Y plots.

Qualcomm Wuxi ZEISS Crossbeam 540 DVIA-MB1000 (MB1000 P47) China trip report — 2017.10.26

DVIA-MB1000 worksheet referenced as MB1000 P47 (중국 출장 보고서 header) with ZEISS-CROSSBEAM 540 for end user Qualcomm at Wuxi (QUALCOMM 1층 연구소). Operator Choi HyoungMun (Daeil System); business trip 17.10.21~17.10.25, measurement 2017.10.24, report written 17.10.26. The Overview line, measurement-summary table, and narrative paragraphs follow the DOCX verbatim. Decorative bitmap on the centred title block (image1) is not republished. The VC-Class plot is placed immediately after the report title line to match DOCX body order; MB1000 internal-program screens and octave-band plots for Z/X/Y follow §2a paragraph-order mapping (image3–8).

QUALCOMM ZEISS Crossbeam 540 DVIA-M1000 installation test data — 2017-10-24 / 2017-10-26

2017 worksheet for ZEISS-Crossbeam 540 at Qualcomm: installation and measurement 2017-10-24, reporting 2017-10-26, engineer CHOI, HYOUNGMUN (DAEIL SYSTEMS). Publishes transmissibility-with-coherence plots and octave-band results for Z, X, and Y; the decorative graphic under the title block is omitted from the public page.

Qualcomm ZEISS CROSSBEAM 540 DVIA-M1000 (MB1000) Installation test data (2017-10-26)

Archived handout-style “Installation Test Data” for a ZEISS CROSSBEAM 540 at Qualcomm on DVIA-M (MB1000). Installation and measurement date 2017-10-24; reporting date 2017-10-26; engineer CHOI, HYOUNGMUN. Published imagery: equipment view after the title block, then Z/X/Y transmissibility with coherence plots and Z/X/Y octave-band plots. No vibration-criteria VC curves or measurement summary table appear in the source document.

ZEISS SIGMA HD DVIA-M1000 Installation Test Data — Qualcomm — 2017.10.26

2017 handout for DVIA-M type (MB1000) installation test data at Qualcomm with ZEISS SIGMA HD: installation and measurement 2017.10.24, reporting 2017.10.26, operator CHOI, HYOUNGMUN (DAEIL SYSTEMS). Publishes transmissibility-with-coherence plots (Z, X, Y) and octave-band results (Z, X, Y). A decorative raster between the model name block and the date fields is omitted from the public page.

HITACHI SU8230 SEM DVIA-MB1000 (MB1000_P52) Vibration Survey — Tier-1 Semiconductor — 2017.09.12

Korean worksheet MB1000_P52 for a HITACHI SU8230 SEM at a Tier-1 Semiconductor facility in Daejeon: trip and report metadata, overview, measurement date and operator, site and equipment model, measurement conditions, VC-Class summary table (floor vs platform), narrative summary lines, VC-Class environment plots for Z/X/Y, and MB1000 internal-program transmissibility plots for Z/X/Y. Measurement 2017-09-11; report 2017-09-12; operators Choi, Hyoung Mun (manager) and Kim, Doo Hyun (assistant manager), DAEIL SYSTEMS. Decorative centred banner raster before the printed title block is not republished.