Xiamen Haichen Zeiss Sigma300 DVIA-MB1000 (P239 · 210820R1) Installation Report — 2021.10.12

DVIA-MB1000 (P239 / internal ref. 210820R1) for Zeiss Sigma300 at Xiamen Haichen — setup and reporting on 2021.10.12, transmissibility summary at 2 / 5 / 10 Hz, and internal-program Z / X / Y plots plus an on-site equipment photograph as in the source.

Huawei TESCAN Solaris GMH DVIA-M1000 Installation Report (MB1000 P249, 210517R4) — 2021.09.29

MB1000 internal-program worksheet (P249, report 210517R4) for TESCAN Solaris GMH with END USER Huawei — transmissibility summary at 2/5/10 Hz and Z/X/Y internal-program plots. Place of installation and place of measurement are N/A on the form.

STM OEM DVIA-MO1000 (P247) Second Setup Installation Report — September 13, 2021

MO1000 internal-program handout for DVIA-MO1000 serial P247 via (second setup). Measurement on 2021-09-10 with summary transmissibility table and Z–X–Y internal program screenshots. Cover-only header raster is omitted from publication.

Thermo Fisher Apreo 2S DVIA-MB1000 (210701R6-2 P242) Installation Report

internal-program handout for DVIA-MB1000 serial 210701R6-2 (platform P242) with Thermo Fisher Scientific Apreo 2S as the target equipment. Operator KIM, DOOHYUN (Daeil System, research engineer); setup and measurement on 2021.08.20; reporting on 2021.09.06. Published figures are the MB1000 internal-program Z/X/Y performance screens only; the Word title-line header raster is omitted from the public gallery. Place of installation and END USER are blank on the form (N/A). The source handout has no Reference / VC criteria appendix.

MB1000 P246 (210701R6-5) internal program worksheet — 2021.09.06

active-mounting worksheet for platform MB1000 P246 serial 210701R6-5 with blank target-equipment lines in the form. Operators Choi HyoungMun and DAEIL SYSTEMS measurement lead; measurement 2021.08.25; setup 2021.08.27; reporting 2021.09.06; template business-trip line 17.12.27~17.12.29. Figures are MO1000 internal-program Z/X/Y axis screens exactly as labeled in the DOCX map; centered title raster under the worksheet heading is omitted. The source worksheet has no Reference / VC appendix.

Hitachi SU8010 DVIA-MB1000 P238 (210708R1-2) internal program handout — 2021.09.06

active-mounting worksheet for platform MB1000 P238 serial 210708R1-2 with HITACHI-SU8010 as the stated target equipment. Operator Choi HyoungMun (Daeil System, research engineer); setup 2021.08.25; reporting 2021.09.06; business trip 17.12.27~17.12.29. Published figures are the MB1000 internal-program Z/X/Y performance screens only; the Word header raster under the title line is omitted from the public gallery. The source handout has no Reference / VC criteria appendix.