Vibration Isolation Case Studies

DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.

Series

Equipment Type

Manufacturer

All Case Studies

1264 case studies
THERMO APREO 2S DVIA-MB1000 (P237) Internal program performance — 2021.08.18

DVIA-MB1000 worksheet P237 for THERMO APREO 2S (measurement dated 2021.08.18; operator Choi, HyoungMun, Daeil System). Setup and overview text follow the DOCX summary tables as published; MB1000 internal-program plots align with Z axis, X axis, and Y axis headings. The decorative raster on the centred title line is not republished.

无锡英诺赛思 ZEISS Sigma 300 DVIA-MB1000 (P235) Internal Program Performance — 2021.08.10

DVIA-MB1000 program MB1000 P235 — Wuxi Yingnuo Technology, target equipment ZEISS Sigma 300. Internal-program plots follow Z axis, X axis, and Y axis headings as in the source. The title-line graphic between the report heading and the setup tables is not republished.

Thermo Fisher Apreo DVIA-M1000 (210420R2) Installation Report — MacDermid Enthone — 2021.08.04

DVIA-M1000 serial 210420R2 for MacDermid Enthone, target equipment Thermo Fisher Scientific FIB-SEM Apreo. The published excerpts are the Vertical, Left-to-Right, and Front-to-Back Transmissibility plots from Data and Image. The ISO/VC reference material in the handout appears as an on-site markdown table instead of a separate figure.

DVIA-MB1000 (P160) Internal program performance — 2021.08.04
Installation Report
DVIA-M Series
08-04-2021

DVIA-MB1000 (P160) Internal program performance — 2021.08.04

DVIA-MB1000 worksheet P160 for (measurement reporting dated 2021.08.04; operator Kim, Doohyun, Daeil System). Overview and transmissibility summary follow the DOCX as published; internal-program plots follow Z axis, X axis, and Y axis headings. The decorative raster on the centred title line is not republished.

KIST TESCAN AMBER X MB1000 site worksheet (P219) — 2021-07-22
Installation Report
DVIA-M Series
07-22-2021

KIST TESCAN AMBER X MB1000 site worksheet (P219) — 2021-07-22

MB1000 handout for platform P219 with TESCAN AMBER X at KIST (L0 2nd floor): setup capture, measurement-chain photos, VC-Class summary table, three Korean follow-up notes with laboratory photographs, MB1000 internal-program plots, and Wave Form plots for Z, X, and Y.

Nexchip Zeiss Crossbeam 550 DVIA-MB1000 (210204R3) Internal Program Performance — Hefei — 2021.06.29

DVIA-MB1000 serial 210204R3 at Nexchip, target equipment ZEISS Crossbeam 550, measurement site Hefei. Internal-program curves follow Z, X, and Y axis captions as mapped from the DOCX (§2a). The ornamental graphic embedded under the document title band is omitted from the public gallery.