Vibration Isolation Case Studies
DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.
Series
Equipment Type
Manufacturer
All Case Studies

Shanghai University Thermo Fisher SEM DVIA-ML1000 Installation Report
Historical handout installation record (220106R8, Aug 2023): Thermofisher SEM on DVIA-ML1000 at Shanghai University — overview, setup dates, and M1000 internal-program Z/X/Y performance plots.

Gemini 360 DVIA-M1000 Internal Performance Report (Shenzhen, 2023)
Shenzhen Special Equipment Inspection Institute — Gemini 360 on DVIA-M1000 (title line SN 220603R4). M1000 internal program performance plots for Z, X, and Y.

SIGMA 300 DVIA-M1000 (230627R3) Installation Report — Dongguan Strong Laser
DVIA-M1000 (serial 230627R3) setup summary for SIGMA 300 at Dongguan Strong Laser Advanced Equipment. The source handout includes target equipment and site lines, operator and trip dates, an Overview block with on-site measurement metadata (2023.08.10), and M1000 internal program Z/X/Y axis performance screenshots. Decorative header logo and title raster omitted; no Reference section in the source.

Tianjin Zhuosheng Scios2 DVIA-M1000 (230626R1) Installation Report
DVIA-M1000 abbreviated worksheet (serial 230626R1). Setup dated 23.07.28 and reporting dated 23.08.03; measurement date 2023.07.28 (Friday) in Tianjin with operator Youngha Lee from DAEIL SYSTEMS. END USER Tianjin Zhuosheng precision Machinery Technology Co., LTD; Target equipment NONE and installation site Tianjin as in the form. The Overview block states the standard DVIA-M1000 sentence only. No vibration specification, equipment status, tuning request, measurement summary table, or Reference section appears in the source. The internal-program section title in the source reads “M1000 internal program performance measurement result”; published figures are three plots labeled Z axis, X axis, and Y axis. Decorative header graphics from the Word file are omitted from public copy.

Thermo Fisher Scios 2 DVIA-M1000 (210322R1) Installation Report — CETC 13 institute (Shijiazhuang)
DVIA-M1000 (serial 210322R1) M1000 internal-program Z/X/Y screenshots for a Thermofisher SCIOS 2 installation at CETC 13 institute, Shijiazhuang (measurement dated 2023.07.27). The published page reproduces Overview and site/end-user rows from the handout plus the three-axis internal-program captures; VC-class summary curves and octave-band plots are absent from this report and were not added. Decorative header/logo embed on the cover line was omitted.

Tier-1 Battery Manufacturer SAIT DVIA-MB1000 (221214R2-1) ZEISS Geminisem 550 Installation Report
Tier-1 Battery Manufacturer SAIT DVIA-MB1000 (221214R2-1): ZEISS Geminisem 550 onsite measurement (July 2023). Summary table compares VC-class labels for Floor vs Active in three axes across 1–10 Hz and 10–80 Hz bands; plots show floor versus platform VC curves.