Vibration Isolation Case Studies

DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.

Series

Equipment Type

Manufacturer

All Case Studies

1264 case studies
Hankook Tire Technodome Hitachi SU8010 DVIA-MB1000 (P38) vibration environment measurement — 2016.12.28

MB1000 program project P38 handout documenting post-installation vibration environment measurement for a Hitachi SU8010-class SEM at Hankook Tire Technodome, Daejeon (report line: 1st floor research building). Measurement 2016-12-27; report authored 2016-12-28 by DAEIL SYSTEMS field engineers Kim Duhyun (Deputy Manager) and Lim Jongwook (Senior Engineer). VC-Class summary for the slab floor versus the DVIA tabletop, VC-Class Z/X/Y plots, and internal-program Z/X/Y transmissibility plots follow DOCX §2a embed-to-heading mapping; centred masthead raster image1 (title block garnish only) omits publication.

Saeron Technology MB1000 P37 setup result — in-house SEM vibration survey with DVIA-MB1000 (2016-12-22)

Survey report dated 22 December 2016 for MB1000 P37 supporting an in-house SEM at Saeron Technology in Uiwang, Gyeonggi-do (5F). Measurement was performed on 21 December under active DVIA-MB1000 control, comparing floor versus platform vibration before and after SEM operation, with VC-class plots and MB1000 internal-program transmissibility captured for vertical and horizontal axes. The decorative header graphic at the very start of the DOCX is not published.

Tongji University (Shanghai) ZEISS SIGMA 300VP DVIA-MB1000 (MB1000 P28) China business trip worksheet — 2016.11.21

Korean-format China business-trip worksheet for MB1000_P28: target ZEISS SIGMA 300VP SEM, setup and vibration-environment work at Shanghai Tongji University on 16–17 Nov 2016; report dated 2016-11-21 by Deputy Lim Jong-wook. The public page publishes the SEM installation photo after the target-equipment line (DOCX image2, §2a), MB1000 internal-program Z / X / Y captures (image3–5), vibration-environment Z / X / Y plots (image6–8), and ~1M× SEM image comparison PASSIVE vs ACTIVE (image9–10 TIFF→WebP). The approval block raster at the document start (Word image1) is omitted.

Guangzhou ENF Hitachi SEM SU8010 DVIA-MB1000 (MB1000 P35) vibration-environment report — 2016.11.11

Korean-format worksheet for MB1000 program line P35 with target microscope HITACHI SEM SU8010 following active isolator deployment at Guangzhou ENF; trip dated 2016-11-09 and report dated 2016-11-11. The VC-Class summary covers the laboratory floor slab and the isolator tabletop, followed by appended Z-, X-, and Y-axis VC environment plots and a supplementary measurement-program capture.

Saeron Technology UB1000 P3 demo result — in-house SEM vibration survey (2016-10-21)

Demo report dated 21 October 2016 for UB1000 P3 at Saeron Technology in Uiwang, Gyeonggi-do, comparing on-site vibration and 100,000× SEM imaging against the existing MB1000 platform on an in-house SEM. Travelers CHOI HYOUNGMUN and LIM JONG UK; measurer LIM JONG UK. Publication includes the in-house SEM photograph, floor versus platform VC-class Z/X/Y plots, and ACTIVE image-comparison captures for MB1000 and UB1000. Decorative header PNG omitted.

Tier-1 Display Manufacturer Giheung MB1000_P30 TESCAN MIRA3 AMU Vibration Environment Measurement Report (2016-10-12)

MB1000_P30 passive vibration isolation setup at Tier-1 Display Manufacturer Giheung with TESCAN MIRA3 AMU as the target tool: September 28, 2016 floor (BASE) versus platform top (TOP) VC-class summary and Z/X/Y VC curves.