Remote tuning — Mongolia University FEI TF20 DVIA-MB3000 (201216R1-4 P16) — 2021.06.08

remote-tuning handout for DVIA-MB3000 serial 201216R1-4 (platform label P16) at Mongolia University, Hohhot (Huhehaote), China, with FEI TF20 (FEI-TEM) as the stated target equipment. Operator Doohyun Kim (Daeil System, research engineer); setup and measurement 2021.06.08; reporting 2021.06.09. Published figures are the MB3000 internal-program Z/X/Y performance screens only; the Word header raster under the title line is omitted from the public gallery. The source handout has no Reference / VC criteria appendix. The performance block title in the Word file reads “MB1000 internal program …” while the report header identifies MB3000.

Apple THERMO FISCHER Quanta DVIA-MB1000 remote VEC (200722R4) Installation Report — 2021.05.18

Remote VEC worksheet for DVIA-MB1000 (serial 200722R4, internal P195) under THERMO FISCHER Quanta at Cupertino, CA for Apple Inc. Operator Doohyun Kim; measurement 2021-05-14; setup and reporting dates as stated on the form; business-trip window per header. Publishes equipment photograph, MB1000 internal program axis plots, and VEC measurement axis composites from Word. The source handout has no Reference / Generic Vibration Criteria section — none was added.

ThermoFisher Talos DVIA-MB3000 (200810R1) Installation Worksheet — 2021.05.12

DVIA-MB3000 (serial 200810R1, platform P11) active-mount worksheet for ThermoFisher-Talos. Reporting date 2021.05.12; summarized transmissibility at 2 Hz, 5 Hz, and 10 Hz with omnidirectional assessment. Published plots: MB1000 internal-program performance measurement and Z/X/Y internal-program graphs; installation photograph not included on the supplied form.

ZEISS Gemini DVIA-MB1000 (201229R3) MB1000 Internal Program — 2021.05.12

MB1000 handout (DVIA-MB1000 serial 201229R3, worksheet MB1000 P215): target equipment Zeiss-Gemini, measurement 2021.05.10, reporting 2021.05.12. Publishes transmissibility summary and Z / X / Y MB1000 internal-program plots. The title-paragraph banner image (image1.png) is omitted on the public page per the same MB1000 title-block handling as nearby MB1000 reports.

Thermo Fisher Scientific DVIA-MB1000 (210416R1 · MB1000 P226) Internal program worksheet — 2021.05.12

DVIA-MB1000 worksheet (platform serial 210416R1, program line MB1000 P226): target equipment name THERMOFISHER, setup 2021.05.10, reporting 2021.05.12. The Overview line, fixed-frequency transmissibility summary table, and MB1000 internal-program Z / X / Y captures follow the DOCX text and §2a paragraph↔embed mapping (image2–image4 → figure_01–03). The centred title-block raster under the MB1000 P226 / 210416R1 head (image1) is omitted as decorative. No Vibration specification or Reference headings appear in the source; none were added.

Visionox (Guangzhou) Thermo Fisher Scientific Helios 5 CX DVIA-MB1000 (210524R4) Installation Report — 2021.05.12

DVIA-MB1000 worksheet (serial 210524R4) for Thermo Fisher Scientific Helios 5 CX at Visionox (Guangzhou). Operator Choi, HyoungMun; setup 21.05.10 and reporting 21.05.12; measurement date 21.06.23 (Tuesday) with Daeil System research engineer Choi, HyoungMun at Visionox (Guangzhou). The source includes a transmissibility summary table (2 Hz / 5 Hz / 10 Hz) and three MB1000 internal-program plots (Z, X, Y). Decorative header raster after the “MB1000 P232 210524R4” title line is omitted on the public page.