Skip to main content

Vibration Isolation Case Studies

DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.

Series

Equipment Type

Manufacturer

All Case Studies

1264 case studies
ZEISS FE-SEM Sigma 360 DVIA-M1000 (241111R1) Installation Report

DVIA-M1000 installation report (serial 241111R1) — ZEISS FE-SEM Sigma 360. Field package. UI-program transmissibility plots and equipment photo; Reference as markdown VC table.

KYKY SEM Self made DVIA-M1000 (241209R1) Installation Report
Installation Report
DVIA-M Series
03-07-2025

KYKY SEM Self made DVIA-M1000 (241209R1) Installation Report

DVIA-M1000 installation report (serial 241209R1). Published figures: tuning-request, vertical-transmissibility, left-to-right-transmissibility, front-to-back-transmissibility, equipment-picture-01. Reference uses the standard Generic Vibration Criteria markdown table.

QRT MST8500 Probe Station DVIA-T67 (250204R2) Installation Report

DVIA-T67 (serial 250204R2) inspection and vibration measurement at Korea Institute of Nano Technology 3F QRT lab on March 7, 2025, for customer QRT. Active-mode imaging noise prompted the visit; MSTech MST8500 probe station with equipment Turned on. VC / Autospectrum / Transmissibility by axis, equipment photo, measurement summary table; Reference as markdown Generic Vibration Criteria table.

National Center for Nanoscience and Technology DVIA-MO1000 (221024R3) Internal Program Performance — 2025.03.05

DVIA-MO1000 serial 221024R3 — National Center for Nanoscience and Technology handout for self-made target equipment, setup and reporting on 2025-03-05. Measurement was performed in Beijing on March 6, 2025. MO1000 internal program performance plots are published for Vertical, Left to Right, and Front to Back. Cover-only header graphics are not republished.

Epin Shanghai STM DVIA-MO1000 (240930R7) Installation Report — March 5, 2025

DVIA-MO1000 second tuning report (serial 240930R7) for Epin STM in Shanghai, China; tuning March 5, 2025 (2nd tuning).

Fudan University JEOL F200 — DVIA-MB3000 (241017R1) Installation Report — 2025.03.04

DVIA-MB3000 active vibration isolation worksheet (serial 241017R1) for a JEOL F200 TEM at Fudan University, with measurements in Shanghai. Setup and reporting 2025.03.04; operators Chaewon Lee and Jonghwa Suh (DAEIL SYSTEMS). Published figures are MB3000 internal-program captures for Vertical, Left to Right, and Front to Back only; the Word raster under the *(MB3000_ 241017R1 Set up)* title block is omitted on the public page. No Reference / VC appendix is present in the source handout.