Vibration Isolation Case Studies
DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.
Series
Equipment Type
Manufacturer
All Case Studies
Chinese Academy of Sciences Institute of Semiconductors Thermo Fisher Helios 5 CX DVIA-M1000 (250619R4) Installation Report
DVIA-M1000 installation report — Thermo Fisher FIB-SEM Helios 5 CX (serial 250619R4), Institute of Semiconductors, Chinese Academy of Sciences in Beijing (channel). Overview states the platform is appropriately installed and functioning as intended. The on-site form has no vibration-specification section. Published figures: tuning-request UI capture, floor vs DVIA-M1000 Transmissibility (vertical, left-to-right, front-to-back), on-site equipment photo; Reference uses the standard Generic Vibration Criteria markdown table. Equipment Condition The equipment is installed/Turned off. No VC curves or Autospectrum plots appear in this report.

COXEM ZEISS FE-SEM SUPRA 55VP DVIA-ULFB1000 Installation Report
DVIA-ULFB1000 (serial 250711R2) installation report for COXEM (End User) with a ZEISS FE-SEM SUPRA 55VP at Migun Techno World Phase 1, Room 2209, Daejeon. Vibration measurement and tuning on 27 Aug 2025 with the tool installed and turned off. Includes vertical and horizontal vibration specification figures, axis VC curves, autospectra, transmissibility, equipment photo, and the standard VC reference table.

COXEM DVIA-ULFB1000 Installation Report
COXEM DVIA-ULFB1000 Installation Report

Tianjin Institute of Hematology ZEISS GeminiSEM 360 DVIA-M1000 (250530R5-1) Installation Report
DVIA-M1000 installation report — ZEISS FE-SEM GeminiSEM 360 (serial 250530R5-1) for Tianjin Institute of Hematology in Tianjin, China. Overview states the platform is appropriately installed and functioning as intended. Equipment condition: The equipment is installed / Turned off. Published figures: tuning-request UI-program capture, Transmissibility (vertical, left-to-right, front-to-back), and on-site equipment photo. No vibration-specification section, measurement-summary table, or VC or Autospectrum figures; Reference uses the generic vibration-criteria markdown table.

Tianjin Institute of Hematology ZEISS Crossbeam 550 FIB-SEM DVIA-M1000 (250530R5-2) Installation Report
DVIA-M1000 installation report — ZEISS FIB-SEM Crossbeam 550 (serial 250530R5-2) for Tianjin Institute of Hematology in Tianjin. Overview states the platform is appropriately installed and functioning as intended. The published form has no separate vibration specification section. Equipment condition: The equipment is installed/Turned off. Tuning request as UI-program capture; vertical, left-to-right, and front-to-back transmissibility; on-site equipment photo; Reference uses the standard Generic Vibration Criteria markdown table. Report written date taken from the cover block.

Hitachi TEM HT7800 DVIA-M1000 (240927R2-1) Installation Report
DVIA-M1000 installation report (serial 240927R2-1) — Hitachi TEM HT7800. Field package. UI-program transmissibility plots and equipment photo; Reference as markdown VC table.