Xiamen Farad Electronics Thermo Fisher Apreo 2S DVIA-M1000 MB1000 Worksheet (211206R2) — 2022-01-24
MB1000 internal-program handout (platform serial 211206R2, worksheet title MB1000 P275) for Thermo Fisher Apreo 2S at CABOT, Xiamen Farad Electronics. Operator Yu Hosang (Daeil Systems); setup 2022-01-19; reporting 2022-01-24. Posts transmissibility summary table, field setup image, and Z/X/Y MB1000 program plots.

UB1000 P24 (200828R4) ZEISS Sigma 300 remote tuning measurement report
UB1000 vibration isolation serial 200828R4 setup and measurement handout (path) for target equipment ZEISS Sigma 300 at a Tier-1 Semiconductor account. Setup and reporting dated 22.01.10 with operator CHOI, HYOUNGMUN; business-trip reference 17.12.27–17.12.29; overview measurement 22.01.10 (Mon). Publication includes the UB1000 internal-program setup screen plus distinct Z / X / Y performance captures, and transmissibility summary at 5 Hz and 10 Hz. Fields left blank on the handout appear as N/A. Reference publishes the Generic Vibration Criteria markdown table only (no supplementary diagram).

UB1000 P26 (210720R4) ZEISS Sigma 300 remote tuning measurement report
UB1000 vibration isolation serial 210720R4 setup report under the target ZEISS Sigma 300 microscope (path). Setup and measurement documentation dated January 2022: transmissibility summary at 5 Hz and 10 Hz for vertical, lateral, and cross-lateral axes, plus UB1000 internal program performance captures for Z, X, and Y. Fields left blank on the handout appear as N/A. Reference publishes the Generic Vibration Criteria markdown table only (no supplementary diagram).

ZEISS Sigma 300 DVIA-MB1000 (210503R7) internal program — 2022-01-07
MB1000 P227 handout — SN 210503R7, target ZEISS Sigma 300. Transmissibility summary at 2/5/10 Hz plus MB1000 internal-program Z/X/Y plots; title-block ornament raster from the Word cover is not republished.

ZEISS Sigma 300 DVIA-MB1000 (P227 / 210503R7) NEMO worksheet — 2022-01-07
NEMO handout MB1000 P227 NEMO 22.01.07.docx — target ZEISS Sigma 300, reporting 22.01.07 (setup 22.01.04). Transmissibility summary at 2/5/10 Hz and MB1000 internal-program Z/X/Y screenshots follow DOCX §2a mapping (rId9–11 → image2–4); the centred title-line ornament (rId8 / image1) is not republished.

Baosteel ZEISS Sigma 300 DVIA-MB1000 (P205) Internal Program Performance — 2021.12.29
DVIA-MB1000 program MB1000 P205 (source MB1000 P205 NEMO 21.12.29.docx) for Baosteel with target equipment ZEISS Sigma 300 at R&D Center 3Floor. Publishes setup field table, Overview, measurement metadata, transmissibility summary at 2/5/10 Hz (Z/X/Y), and MB1000 internal-program plots under Z axis, X axis, and Y axis in DOCX embed order (image2–4). The centered title-line graphic before the setup fields (word/media image1) is omitted from the public page.