Vibration Isolation Case Studies
DAEIL SYSTEMS engineers active vibration isolation systems for the world's most demanding nanoscale imaging and metrology environments.
Series
Equipment Type
Manufacturer
All Case Studies

University of Science and Technology of China (Hefei) Unisoku USM1400SA DVIA-M-SOST (230818R6-1) Internal Program — 2024.06.05
DVIA-M-SOST internal program worksheet (serial 230818R6-1) for University of Science and Technology of China (Hefei) with target equipment Unisoku USM1400SA. Overview and in-form metadata match the source; M1000 internal program screenshots are labeled Vertical, Left to Right, and Front to Back. The JPEG under the `(M-SOST_ 230818R6-1 Set-up)` title block (rId8 / image1.jpeg) was treated as header decoration and omitted from the public page. No vibration specification, equipment status, tuning request, measurement summary table, or Reference section appears in the source.

Thermo Fisher Spectra 300 S/TEM DVIA-MB3000 (240415R3-1) — Shenzhen Weiguang, 2024-05-30
Shenzhen Weiguang — Thermo Fisher Spectra 300 S/TEM on DVIA-MB3000 serial 240415R3-1. M3000 internal program performance plots (Vertical, Left to Right, Front to Back) from the 2024.05.30 measurement; reporting dated 2024.07.05. Engineer Byeonghun Cho (DAEIL SYSTEMS).

DVIA-M1000 MB1000 Internal Program Measurement (230509R6-1) — 2024.05.28
DVIA-M1000 form line (M1000_ 230509R6-1); setup 24.05.28 / reporting 24.07.05 / measurement 2024.05.28; Target equipment, installation place, end user, site line, and equipment model were blank or placeholder in the source and are published as N/A. Screenshots: Vertical, Left to Right, and Front to Back from the MB1000 internal program only; Reference is the standard Generic Vibration Criteria markdown table.

ZEISS Sigma360 SEM DVIA-M1000 (230926R1) Installation Report — Changsha
DVIA-M1000 installation report (serial 230926R1) — ZEISS SEM Sigma360 in Changsha. Field report with internal-program transmissibility screenshots (Vertical, Left to Right, Front to Back).

Wuxi Photon Park NX20 DVIA-M1000 MB1000 Internal Program Report
Wuxi Photon (Wuxi) — Park NX20 on DVIA-M1000 (MB1000 handout 231214R7-2). Publishes the site equipment photograph plus MB1000 internal-program Vertical, Left to Right, and Front to Back results (measurement dated 2024.05.21).

Hainan University Thermo Fisher Spectra 300 DVIA-MB3000 (231004R3-1) Installation Report — 2024.05.09
DVIA-MB3000 abbreviated internal-program worksheet for serial 231004R3-1 (source MB3000_231004R3-1_24.05.09.docx). Target equipment Thermo Fisher Spectra 300 for Hainan University (海南大学) in Hainan (海南); date of setup 24.05.09 and date of reporting 24.07.05 per the form; operator Lee, Chaewon in the header block; measurement dated 2024.05.09 (Thursday); overview uses the DVIA-MB3000 wording and lists Operator as DAEIL SYSTEMS Chaewon Lee in the worksheet line order. No vibration specification, equipment status, tuning request, measurement summary table, or Reference section appears in the source. Internal-program plots follow Vertical, Left to Right, and Front to Back. The JPEG under `(MB3000_ 231004R3-1 Set up)` was treated as decorative title-block artwork and omitted from the public page.